For PRO-90-6601 SES board:
NOTE: The upgrade process is done twice. The first time needs a
jumper in JP8. The second time does not need a jumper.
1. Power off the RAID system. Remove the SES Module. Insert a jumper in JP8 of
SES board PRO-90-6601.
2. Insert the SES module into the RAID subsystem. Connect RS232 serial cable to
the RS232 port of SES module.
3. Power on RAID subsystem. Configure terminal settings as follows:
Baud Rate: 38400
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
4. Open terminal console. Type “proses upgrade”.