MicroNet Fibre to SAS/SATA II RAID Subsystem Instrukcja Użytkownika Strona 157

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 156
FIBRE-to-SAS/SATA RAID SUBSYSTEM
User Manual
157
4. To upgrade the controller firmware with bridge firmware 1.21:
a. Login to proRAID Manager.
b. Click menu "Administration > Service Options > Controller Services >
Upgrade Controller >".
NOTE: Please stop all IO operations to the RAID subsystem while
upgrade takes place.
NOTE: Firmware upgrade process will auto-upgrade the second
controller if you have redundant controllers in the RAID subsystem.
c. Warning message will be displayed. Click “Yes” to start upgrade process which
takes several minutes.
d. Select the controller firmware binary file (version 1.21).
e. When “Confirm Firmware Details” message box is displayed, select “Yes” to
confirm upgrade.
f. Upgrade process will start. Verify if new firmware is downloaded successfully.
5. Reset the controller(s) when prompted.
a. Controller board(s) must to be reset. Select “Yes” to reset controller(s).
b. Progress status of “Resetting Controller(s)” will be displayed.
c. Verify if new firmware is updated in Monitoring Æ System Information.
Przeglądanie stron 156
1 2 ... 152 153 154 155 156 157 158 159 160

Komentarze do niniejszej Instrukcji

Brak uwag