MicroNet Fibre to SAS/SATA II RAID Subsystem Instrukcja Użytkownika Strona 111

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 138
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 110
Fibre to SAS/SATA II RAID Subsystem
User Manual
111
6.3.1.1 Replacing Controller Module with Plate Cover
When replacing a failed Controller Module with Plate Cover, please follow these steps:
1. Loosen thumbscrews of the failed Controller Module.
2. Use the Controller Module handle to remove the failed Controller Module from the
subsystem.
3. Insert the Controller Plate Cover.
Controller Module Plate Cover
4. Tighten the thumbscrews of the Controller Plate Cover.
When replacing a failed component online, it is not recommended to
remove the failed component for a long period of time; proper air flow
within the enclosure might fail causing high controller/disk drive
temperature.